Failed Drive Replacement

Re: Failed Drive Replacement

Postby hvymetal86 » Wed Jun 14, 2017 1:10 pm

Thank you! Speed has increased significantly:
Code: Select all
root@HvyMtlNAS:/ # cat /proc/mdstat
Personalities : [linear] [raid0] [raid1] [raid10] [raid6] [raid5] [raid4]
md0 : active raid5 sdc8[5] sda8[0] sde8[4] sdd8[3] sdb8[1]
      7802449920 blocks level 5, 64k chunk, algorithm 2 [5/4] [UU_UU]
      [===>.................]  recovery = 15.3% (298934996/1950612480) finish=693.0min speed=39721K/sec
hvymetal86
Donator VIP
Donator VIP
 
Posts: 121
Joined: Mon May 11, 2015 3:42 pm

Re: Failed Drive Replacement

Postby Jocko » Wed Jun 14, 2017 5:46 pm

Indeed it is much better: 10 hours for recovery a raid5 with 5 2TB disks is the usual time on a 5big2
Jocko
Site Admin - expert
 
Posts: 11529
Joined: Tue Apr 12, 2011 4:48 pm
Location: Orleans, France

Re: Failed Drive Replacement

Postby hvymetal86 » Thu Jun 15, 2017 1:35 am

RAID rebuild has finished successfully and now I have started the conversion from ext3 to ext4.
hvymetal86
Donator VIP
Donator VIP
 
Posts: 121
Joined: Mon May 11, 2015 3:42 pm

Re: Failed Drive Replacement

Postby hvymetal86 » Thu Jun 15, 2017 12:03 pm

Conversion was successful:
Code: Select all
NAS server in Setup Mode

(re-)Start the setup task :   Convert filesystem on the data partition

Started on:   14 June 2017, 21:31:25
Ended at:   15 June 2017, 07:39:34
Setup task convert.sh is now running
Found disk: sda(Z4Z1CTME)
Found disk: sdb(35PTHU4AS)
Found disk: sdc(W1F086KE)
Found disk: sdd(Z4Z1BXYD)
Found disk: sde(35PTJZRAS)
Convert md0 to ext4:
Check the file system before converting (please wait, take a long time... ca 1 hour/TB)
=>e2fsck 1.42.11 (09-Jul-2014)
Pass 1: Checking inodes, blocks, and sizes
Pass 2: Checking directory structure
Pass 3: Checking directory connectivity
Pass 4: Checking reference counts
Pass 5: Checking group summary information
/dev/md0: 151551/243826688 files (58.5% non-contiguous), 1729663829/1950612480 blocks
tune2fs 1.42.11 (09-Jul-2014)
Optimize filesystem directories (please wait, take a long time... ca 1 hour/TB)
=>e2fsck 1.42.11 (09-Jul-2014)
Pass 1: Checking inodes, blocks, and sizes
Pass 2: Checking directory structure
Pass 3: Checking directory connectivity
Pass 3A: Optimizing directories
Pass 4: Checking reference counts
Pass 5: Checking group summary information
/dev/md0: ***** FILE SYSTEM WAS MODIFIED *****
/dev/md0: 151551/243826688 files (58.5% non-contiguous), 1729663791/1950612480 blocks
Ok: convert filesystem on md0 successful
Setup task convert.sh is ended
Files are intact. Thanks a bunch for your help! I'm gonna use that donate button :)
hvymetal86
Donator VIP
Donator VIP
 
Posts: 121
Joined: Mon May 11, 2015 3:42 pm

Re: Failed Drive Replacement

Postby Jocko » Thu Jun 15, 2017 3:34 pm

Nice you succeeded to do all what you wanted. :-D
Jocko
Site Admin - expert
 
Posts: 11529
Joined: Tue Apr 12, 2011 4:48 pm
Location: Orleans, France

Previous

Return to Lacie 5big Network vs2

Who is online

Users browsing this forum: No registered users and 10 guests