Hi samrise,
Sorry but it was the expected behaviour and that confirms you can not include in a same raid ms-dos and gpt table.
Now, you need to backup your data on sda8. (If your data size on md0 is too big to store in sda8, you need to use an USB disk).
So,
- Select again as fs type 83 on sda8, and reboot the nas. Vol-A should exist again
- if md0 is the addons volume, select Vol-A as it with the option "Move the technical share" in the main setup menu
- After if there are other shares set on md0 (should be volume RD5-0), move them by using the move feature of the edit share menu.
Then check if all shares are on Vol-A (see shares table)
-Now you can destroy md0 by following the tutorial for RAID5
but do not reboot the NAS-Use gdisk to destroy your gpt table on sd[bcde]
-Use fdisk to build the new ms-dos table by following this Howto
http://plugout.net/download/file.php?id=3823(we forgot to include it in the topic for fvdw-sl console 5.5)
-Reboot the nas, you should have now 5 volumes (Vol-A, Vol-B,...Vol-E)
-Build the new raid by following the Chapter II of this tutorials
Note: all these steps require time